{"id":1126,"date":"2011-05-11T06:33:01","date_gmt":"2011-05-11T06:33:01","guid":{"rendered":"http:\/\/www.esds.co.in\/blog\/?p=1126"},"modified":"2014-03-18T12:17:49","modified_gmt":"2014-03-18T12:17:49","slug":"tiaeia-942-en-50173-5-iso-iec-24764-standards-for-data-centers","status":"publish","type":"post","link":"https:\/\/www.esds.co.in\/blog\/tiaeia-942-en-50173-5-iso-iec-24764-standards-for-data-centers\/","title":{"rendered":"TIA\/EIA-942, EN 50173-5, ISO \/ IEC 24764 Standards"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-1127\" title=\"Standards-For-Data-Centers\" alt=\"\" src=\"https:\/\/www.esds.co.in\/blog\/wp-content\/uploads\/2011\/05\/Standards-For-Data-Centers.jpg\" width=\"675\" height=\"311\" srcset=\"https:\/\/www.esds.co.in\/blog\/wp-content\/uploads\/2011\/05\/Standards-For-Data-Centers.jpg 675w, https:\/\/www.esds.co.in\/blog\/wp-content\/uploads\/2011\/05\/Standards-For-Data-Centers-300x138.jpg 300w\" sizes=\"auto, (max-width: 675px) 100vw, 675px\" \/><\/p>\n<p>The development and design of data centers is based on a number of standards, specifically designed for data centers. The most commonly used standard for developing and designing the data center &#8211; is TIA EIA 942 standard-Telecommunications Infrastructure Standard for Data Centers. This standard was adopted by the telecommunications industry association, and gave a major boost for industry development and data center. The standard was starting point for developing a European standard EN 50173-5\u00a0 and the international standard ISO \/ IEC 24764, concerning the design issues of SCS in the data center.<\/p>\n<p><strong>TIA\/EIA-942 Standard consider the following issues related to the design and organization of data centers:<\/strong><\/p>\n<ul>\n<li>The general approach to designing data centers;<\/li>\n<li>Structure and Architecture of SCS in the data center;<\/li>\n<li>Requirements for premises and territories, is scheduled to deploy data center;<\/li>\n<li>Architectural solutions for data centers;<\/li>\n<li>Approaches to the design of cooling systems, power supply in the data center;<\/li>\n<li>Building a system of cable channels for data centers;<\/li>\n<li>Redundancy and reliability levels tier3 data centers.<\/li>\n<\/ul>\n<p>A new version of the TIA\/EIA-942 standard is expected till the end of 2012, which will be rewritten and improved, taking the fact into account that the association was adopted by the telecommunications industry and a new standard for SCS TIA\/EIA-568C has gained extensive experience designing and creating Data Centers\u00a0 based on the use of new technologies and technical solutions.<\/p>\n<p>In addition to standards adopted by the European standard EN 50173-5 &#8220;Information Technology &#8211; Generic Cabling Systems, the second version of the international standard ISO \/ IEC 24764\u00a0 &#8220;Information technology &#8211; Generic cabling systems for Data Centres, was not been accepted and approved by the working group.<\/p>\n<p>The European standard EN 50173-5\u00a0 and the international standard ISO \/ IEC 24764 relate to matters of constructing a structured cabling system in data centers.<\/p>\n<ul>\n<li>The European standard EN 50173-5 covers the following issues:<\/li>\n<li>Structures, hierarchy and functional elements of the SCS in the data center ;<\/li>\n<li>Interfaces in a structured cabling system;<\/li>\n<li>Requirements for the channel and cable lines in the copper and optical SCA;<\/li>\n<li>Requirements for the connecting and distribution equipment;<\/li>\n<li>Requirements for cords and connectors used in data centers.<\/li>\n<\/ul>\n<p>International standards are developed and based on European standards and includes in addition to issues addressed by the standard EN 50173-5 is the question of redundancy, grounding, marking and identification of passive components, making use of high-density optical cable system. This standard provides specific requirements for minimum and maximum length of the cable system.<\/p>\n<p>Despite the fact that the standards of <strong>TIA\/EIA-942, EN 50173-5 and ISO \/ IEC 24764 <\/strong>are pretty much similar, but there are differences in standards.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The development and design of data centers is based on a number of standards, specifically designed for data centers. The most commonly used standard for developing and designing the data center &#8211; is TIA EIA 942 standard-Telecommunications Infrastructure Standard for Data Centers. This standard was adopted by the telecommunications industry association, and gave a major&#8230; <\/p>\n<div class=\"clear\"><\/div>\n<p><a href=\"https:\/\/www.esds.co.in\/blog\/tiaeia-942-en-50173-5-iso-iec-24764-standards-for-data-centers\/\" class=\"gdlr-button small excerpt-read-more\">Read More<\/a><\/p>\n","protected":false},"author":5,"featured_media":1127,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1],"tags":[342,340,341,339],"class_list":["post-1126","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-centers","tag-data-center-standards","tag-en-50173-5","tag-iso-iec-24764","tag-tiaeia-942"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/posts\/1126","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/comments?post=1126"}],"version-history":[{"count":8,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/posts\/1126\/revisions"}],"predecessor-version":[{"id":4941,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/posts\/1126\/revisions\/4941"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/media\/1127"}],"wp:attachment":[{"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/media?parent=1126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/categories?post=1126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.esds.co.in\/blog\/wp-json\/wp\/v2\/tags?post=1126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}